Specification reference

Operable Partitions — Specification & CSI MasterFormat 10 22 19

Operable and folding wall systems are commonly specified in Division 10 (Specialties); MasterFormat 2014 lists Demountable Partitions under 10 22 19. This page is a specification reference, not a product data sheet.

Buyers ask: "Where do operable partitions sit in a project manual?"

The specification problem

The three terms are not interchangeable. A demountable partition is a relocatable fixed wall; an operable partition is a top-hung wall that moves on an overhead track and parks; a folding partition describes how the leaves are arranged. If a specification mixes them, the bids will not be comparable.

This page is a specification reference, not a product data sheet. Published model data is on the product pages and in the files under Downloads.

These are selection notes, not a new product line. The panels, models and published data are on the product pages. No acoustic or fire figure is published here, and no model is compared against another on an application page.

What to specify

The items below are the ones that decide whether the wall works. Fix them before the shop drawing is issued.

01

Opening schedule

Width, finished height and the ceiling/soffit build-up at the track line for every opening.

02

Subdivision and parking

The closed positions, the number of panels and the parking pocket drawn on the plan, with clear space in front of the pocket.

03

Structural load path

Hanger positions and the loads they deliver, with the support steelwork designed by the project structural engineer.

04

Acoustic requirement

State the target and the test standard. Published figures are quoted only for the build that was tested, under the standard actually used.

05

Fire requirement

Quote the classification against the standard actually tested. Different standards are not interchangeable.

06

Pass doors and faces

Pass door side and swing, edge detail, and the specified finish, all fixed at order stage.

07

Operation

Manual, semi-automatic or fully automatic seal operation, named against the panel model that can carry it.

08

Submittals

Shop drawings, hanger schedule, stacking geometry, finish samples, test reports for the actual build, and the maintenance manual.

Configuration & model selection

Our standard submittal set is: a shop drawing for the opening, the panel schedule, the hanger point schedule, the stacking geometry with the pocket dimension, the finish selection, and the test documentation that applies to the specified build. Every quotation is issued with a shop drawing.

The Partition Specification is a generic specification text for the project manual. It is a starting point, not a final document — the project-specific figures come from the shop drawing.

Data conventions. Rw (ISO 717-1) and STC (ASTM E413 / E90) are different ratings and are not converted, averaged or derived from one another. BS 476, EN 13501-1 and ASTM E84 classifications are quoted only against the standard actually tested.

Data for this room

A room type does not carry performance values. Cells marked — are established from the project, not guessed here.

ItemValueHow it is established
MasterFormat sectionDivision 10 / 10 22 19Follow the project manual's own division structure.
Wall typeTop-hung operable partitionNo floor track.
ConfigurationsSingle panel / paired hinged / tall openings / motorizedModel selection is separate from configuration.
Acoustic rating—Quote against the standard actually tested.
Fire classification—Quote against the standard actually tested.
Shop drawingIssued with every quotationProject-specific, not a catalogue cut.
Why most cells read —. A room type does not have a fixed acoustic, fire or load value: those figures belong to a tested panel build and a tested assembly, not to a room. We do not convert Rw (ISO 717-1) into STC (ASTM E413 / E90), we do not average or derive one from the other, and we do not treat one fire classification as equivalent to another. Send the opening and the project's stated target; we will confirm what can actually be published for that build, against the standard that was tested.

Frequently asked questions

▸Which MasterFormat section should I use for an operable partition?
Operable and folding wall systems are commonly specified in Division 10 (Specialties); MasterFormat 2014 lists Demountable Partitions under 10 22 19. Glazed systems can also involve Division 08 glazing expertise. Follow the division structure of the project manual, and describe the wall as top-hung and operable so it is not bid as a fixed relocatable partition.
▸What is the difference between demountable and operable?
A demountable partition is a relocatable fixed wall that is taken down and re-erected when a layout changes. An operable partition hangs from an overhead track, moves into position and parks in a pocket, with no floor track. They solve different problems and should not be specified as one item.
▸What does the submittal include?
A shop drawing for the opening, the panel and hanger point schedules, the stacking geometry with the pocket dimension, the finish selection, the test documentation for the specified build, and the maintenance manual. We issue a shop drawing with every quotation.
▸Will you state an STC value for our project?
We quote published figures only for the build that was tested, under the standard actually used. Rw (ISO 717-1) and STC (ASTM E413 / E90) are not converted or derived from one another. State your target and test standard in the specification, and we will confirm what can be documented for the build — see the STC Acoustic Guide.

Need a shop drawing for your opening?

Send the opening dimensions, the finished ceiling build-up and your subdivision plan. We will confirm the panel schedule, hanger points and stacking geometry, and tell you which model we would quote.