Application 05 of 06

Operable Partitions for Restaurants & Private Dining

A restaurant divider is opened and closed around service, often by the same person who is setting the room. If the sequence is slow or awkward, staff will simply leave the wall closed.

Buyers ask: "Can a dining room be closed off for a private event and opened again the same day?"

The specification problem

The floor is a working surface: tables move, spills happen, and a floor track would collect dirt exactly where people walk. A top-hung wall keeps the floor clear.

The closed wall becomes a backdrop for a private event, so the finish and the service pass door matter as much as the mechanism.

These are selection notes, not a new product line. The panels, models and published data are on the product pages. No acoustic or fire figure is published here, and no model is compared against another on an application page.

What to specify

The items below are the ones that decide whether the wall works. Fix them before the shop drawing is issued.

01

Finish

A face that can be cleaned with the venue's normal products. Vinyl, melamine and HPL options are in the colour cards under Downloads; confirm cleaning compatibility before specifying.

02

Floor

No floor track. The load goes into the overhead structure, so confirm the support above the ceiling before the fit-out is closed.

03

Operation

One person, one short sequence. Manual lever operation is standard on NW831 and NW840.

04

Service access

A pass door in the wall lets staff serve the private room without opening the whole partition. Fix its position and swing on the shop drawing.

05

Parking

The stack must not block the service route or the fire exit when the room is open. Draw the pocket on the furniture plan.

Configuration & model selection

Single-panel and paired-hinged configurations are both used; the choice follows the opening and where the stack can be hidden. See Single Panel and Folding.

Model selection (NW831 / NW840 / NW840-W) follows height, finish and the seal mode. The model matrix is on How to Choose.

Send the furniture plan and the finish preference. We will return a shop drawing showing the pocket position, the pass door and the panel schedule.

Operating modes are model-bound. NW831 and NW840 are manual only; semi-automatic and fully automatic seal operation is available on NW840-W only. A powered seal is a model decision, not an accessory added later.

Data for this room

A room type does not carry performance values. Cells marked — are established from the project, not guessed here.

ItemValueHow it is established
Opening width—Confirm at finished floor level.
Finished panel height—Confirm against the finished ceiling.
Floor trackNone (top-hung)Load carried by the overhead structure.
Seal operationManual (standard)Semi-auto / fully-auto on NW840-W only.
Acoustic target—State the project target and the test standard.
Fire classification—Quote the standard actually tested.
Why most cells read —. A room type does not have a fixed acoustic, fire or load value: those figures belong to a tested panel build and a tested assembly, not to a room. We do not convert Rw (ISO 717-1) into STC (ASTM E413 / E90), we do not average or derive one from the other, and we do not treat one fire classification as equivalent to another. Send the opening and the project's stated target; we will confirm what can actually be published for that build, against the standard that was tested.

Frequently asked questions

▸Is there a floor track to clean around?
No. NEUWALL operable partitions are top-hung, so the floor is clear and there is no recessed channel to collect spills. The panel load is carried by the structure above the ceiling.
▸Which finish is easiest to clean?
The published vinyl, melamine and HPL colour cards under Downloads show the available faces. Tell us which cleaning products the venue uses and we will confirm compatibility in writing; we do not publish a chemical-resistance rating for a room type.
▸Can staff serve the private room without opening the wall?
Yes — specify a pass door in one panel leaf. Its position and swing are fixed at order stage, so mark the service route on the plan before the shop drawing is approved. See the Passdoor Drawings.
▸Where does the wall go when the restaurant is open?
Into a parking pocket at one end of the run. Its depth is set by the panel count and stacking geometry, and it should be drawn on the furniture plan so it does not block a service route or an exit.

Need a shop drawing for your opening?

Send the opening dimensions, the finished ceiling build-up and your subdivision plan. We will confirm the panel schedule, hanger points and stacking geometry, and tell you which model we would quote.