Operable Glass Walls / Frameless system
Movable Frameless Glass Wall
A top-hung wall of individual 10 mm or 12 mm toughened glass panels that slide and park with no floor track. The glass is held only at its top and bottom edges, with no vertical frame between panels.
- Floor track
- None — top-hung
- Glass
- 10 / 12 mm toughened
- Max height
- 3 000 mm
- Panel width
- 700 – 1 200 mm

What is a movable frameless glass wall?
A movable frameless glass wall is a top-hung, individually operated glazed partition. Each panel is a single pane of 10 mm or 12 mm toughened safety glass, clipped into a 25 mm × 25 mm aluminium head and floor channel with a clear PVC gasket. Roller carriers in an overhead track carry the weight; a floor pin locates each panel when the wall is closed. There is no running track in the floor. Panels are 700–1 200 mm wide, up to 3 000 mm high, and the assembly is 25 mm overall.
Open the wall and the panels slide along the track and park out of the way, leaving one large space. Close it and the panes meet at a clear dry PVC joint, so the wall reads as one continuous sheet of glass.
In plain English
Imagine a wall made almost entirely of glass. Every pane hangs from the ceiling, so the floor underneath stays completely clear — nothing to trip over and no channel to collect dirt. When you want one big room, the panes slide away and park. Put them back and the room divides again. There are no metal posts between the panes, only a narrow clear joint.
Each panel is individually operated, slides along the overhead track and parks away. It is not a fixed partition.
No vertical aluminium frame around or between the panes. The glass is clipped at its top and bottom edges only.
The glazing is the wall, not a window set into a wall. Daylight and the view pass through.
Other names for the same product
Architects, contractors and search engines use several names for this one system. If your documents use any of the wording below, you are in the right place:
Why specify a frameless glass wall?
Three reasons buyers choose this system over a framed glass wall or a fixed partition.
No floor track
The floor stays completely clear. There is no recessed channel to clean, no trip hazard and no break in the floor finish — the view and the flooring run straight through.
One continuous glass face
With no vertical frames between panels, the wall reads as a single sheet of glass. It suits spaces where the architecture should stay visible.
Daylight and flexibility
Keep borrowed light and a long sightline, then divide the room only when you need to. Panels park out of the way when the space is open.
How it works, from ceiling to floor
Four details explain the whole system, then an enlarged view of the hanger-to-clamp connection. The photographs show the actual components.

The ceiling carries the weight
A track is fixed to the structure above the ceiling line. Roller carriers run inside it and each glass panel hangs from its carrier on an adjustable threaded rod.
Top-hung / top-supported system. The load path above the track must be verified by the project structural engineer.

The glass is held at two edges only
Short aluminium clamp blocks grip the top and bottom edges of the glass, with a clear PVC gasket between metal and glass. Nothing runs up the sides of the pane.
Pre-finished 25 mm × 25 mm aluminium head and floor channel; clear PVC glazing gasket.

One pin in the floor, not a track
When the wall is closed, a floor pin locates the panel at a single point. A keyed floor lock secures the closing panel. The rest of the floor stays clear.
Panel can be fixed to the ground by floor pin. No track on the floor.

Panes meet at a clear joint
Adjacent panes meet at a clear dry PVC joint, so the wall reads as one continuous sheet of glass. A hinged glass pass door gives access without moving the panels.
Clear dry PVC joint; satin stainless steel lever latch and hinge.
Trolley-to-clamp connection — step 1, enlarged
Two roller assemblies sit on each glass clamp, spaced along the panel width. A threaded rod passes through both rollers and is locked into the clamp top with a nut and washer; the rollers run inside the suspended overhead track. In plain English: the ceiling track carries the wheels, the rod hangs the clamp, and the clamp holds the glass.

Frameless or framed — which one do I need?
Both are operable glass walls. The right choice depends on what leads the design: the look, or the published acoustic rating.
| Item | Frameless (this page) | Framed operable glass wall |
|---|---|---|
| Glazing | Single 10 mm or 12 mm toughened glass | Double-glazed unit in an aluminium frame |
| Vertical frame between panels | None; clear dry PVC joint | Visible aluminium frame |
| Floor track | None | None |
| Published acoustic rating | Stated on this page | Higher published Rw rating; stated on its own product page |
| Choose it when | Daylight and a minimal all-glass look lead | A higher stated acoustic rating leads |
Technical specifications
Every value below is taken from the two-page NEUWALL frameless glass partitioning source sheet supplied for this product. The right-hand column names the section it comes from.
| Item | Value as stated | Where it is stated |
|---|---|---|
| System type | Top-hung; no floor track | General Description, source sheet |
| Glass | 10 mm or 12 mm single toughened safety glass, depending on height required | Glazed Module |
| Framework | Pre-finished 25 mm × 25 mm aluminium head and floor channel | Framework |
| Glazing gasket | Clear PVC glazing gasket to head and floor channel | Glazed Module |
| Panel joint | Clear dry PVC joint | Panel Joint |
| Panel width (module) | 700 mm – 1 200 mm maximum | Module |
| Height | Up to 3 000 mm | Height |
| Overall thickness | 25 mm | Thickness |
| Dimensional tolerance | ± 5 mm | Tolerance |
| Weight | Approximately 25.00 kg/m² for 10 mm glass; 30.00 kg/m² for 12 mm glass | Weight |
| Floor fixing | Panel can be fixed to the ground by floor pin | General Description |
| Glass flatness | Toughened glass cannot be supplied completely flat. Maximum permitted deviation from a straight line is 0.30% (3 mm per metre run), measured across the full pane on the concave surface and in the vertical plane, supported at all four edges | Glass Tolerances |
| Vertical edge tolerance | 3 mm – 5 mm to frameless glass doors, assuming a flat and level floor and ceiling; may increase subject to prevailing site conditions | Glass Tolerances |
| Acoustic – 10 mm | Up to Rw 32 dB | Acoustic Performance |
| Acoustic – 12 mm | Up to Rw 33 dB | Acoustic Performance |
| Pass door | Hinged glass pass door; satin stainless steel lever latch and hinge as standard; additional finishes and levers available as optional extra | Accessories |
| Finishes | Satin anodised or polyester powder coating to all exposed aluminium components, in a wide range of colours as standard | Finishes |
| Manifestation | A wide range of film manifestation and screen printing available as an optional extra | Accessories |
What the acoustic figures mean
A single pane of glass does not isolate sound the way a solid or double-glazed operable wall does. Here is exactly what the source sheet states.
Installed performance also depends on the surrounding structure, the head detail and how the perimeter is sealed — none of which is a property of the glass panel alone. For the difference between the two rating systems, see the STC Acoustic Guide.
Plain-language glossary
The terms that appear in specifications and in our quotations, without the jargon.
Technical drawings
The same NEUWALL Series 40 elevation shown twice: a line drawing for the drawing register, and a rendered view for a quick visual check.


10 mm glass build
The supplied material also includes an elevation and a vertical section for the 10 mm variant. They are shown separately because the callouts belong to that build and are not carried into the specification table above.


Components and hardware
Four more close-up views of the overhead track and its running gear. The twin roller hanger, clamp blocks, floor lock and pass door hinge are shown in How it works above.




Where it works
Specified wherever a space has to divide without losing daylight or the sightline.

Keep daylight in a lobby or pre-function area, then close the glass wall for a private function without adding a visible frame.
Divide a boardroom or collaboration space while keeping visual connection and borrowed light.
Create a clean glazed frontage that can be opened up for events or product launches.
Separate an interior from a courtyard, pool or terrace without breaking the view or the floor finish.
Finishes, glass and door options
Fixed at order stage so the shop drawing matches what is manufactured.
Glass build
10 mm or 12 mm single toughened safety glass, selected according to the height required. Both builds are covered by the source sheet.
Aluminium finish
Satin anodised or polyester powder coating to all exposed aluminium components, in a wide range of colours as standard.
Manifestation
A wide range of film manifestation and screen printing is available as an optional extra. Useful for safety marking and partial visual privacy.
Door furniture
Satin stainless steel lever latch and hinge as standard in the sheet; additional finishes and levers are an optional extra.
Installation, tolerances and what we need from you
Glass is heavy, and it is never perfectly flat. These points belong in the design, not in a snag list.
- Structure above the track. The system is top-hung. The load path above the track must be verified by the project structural engineer before the ceiling is closed.
- Flat and level floor and ceiling. The 3–5 mm vertical edge tolerance to frameless glass doors assumes a flat and level floor and ceiling. Site conditions may increase it.
- Glass flatness. Toughened glass cannot be supplied completely flat. The maximum permitted deviation from a straight line is 0.30% (3 mm per metre run), measured across the full pane on the concave surface and in the vertical plane, supported at all four edges.
- Overall tolerance. ± 5 mm. Allow for it at the head, the jambs and the floor pin positions.
- Handling. Panels weigh approximately 25.00 kg/m² for 10 mm glass and 30.00 kg/m² for 12 mm glass. We recommend a trained installer with glass handling equipment, and we do not recommend site self-assembly by a team without operable glass wall experience.
To issue a quotation and a shop drawing
Send the opening width and finished height, the ceiling or soffit build-up at the track line, the subdivision plan with the parking position, your preferred glass build, the pass door position and swing, and the finish. We will return the panel schedule, hanger points and the head and floor details.
How is this product specified?
A compact checklist for architects, specifiers and contractors working from a North American three-part (General / Products / Execution) project manual.
In a North American project manual this product type is specified under Division 10 (Specialties), Operable Partitions; CSI-format technical data for glazed operable partitions prints the section as 10 22 26. Confirm the number against the MasterFormat edition used on your project.
Related work is normally split across Division 03 (concrete tolerances), Division 05 (primary structural support and pre-punched steel at the track line), Division 06 (head and jamb blocking), Division 08 (lock cylinders and keying) and Division 09 (ceiling and wall framing).
Product data for every panel, component and accessory: materials, construction, finishes, installation and operating instructions.
Shop drawings with plans, elevations, sections, attachment details, opening and storage dimensions, panel weights, required clearances, hardware and track positions, floor tolerances and direction of travel. Setting drawings for embedded items and the support beam template, finish samples, and an operation and maintenance manual at handover.
Specification writers commonly cite ASTM E557 for opening preparation and installation of operable partitions, ANSI Z97.1 and CPSC 16 CFR 1201 for safety glazing, ASTM C1036 and ASTM C1048 for the glass, and ASTM B221 for aluminium extrusions.
These are standards named in a project specification context; they are not test results for this product. Confirm which edition applies to your project.
A project-specific submittal set: product data, shop drawings (plans, elevations, sections, attachment details, panel weights, hardware and track positions), setting drawings, finish samples and an operation and maintenance manual.
Send the opening dimensions, ceiling build-up, subdivision plan, glass build, pass door position and finish. We return the full set before manufacture.
Downloads
The source sheet and both drawing sets supplied for this product. Ask us for a project-specific shop drawing set for your opening.
Movable Frameless Glass Wall - Technical Data
The two-page source sheet: construction, glass, dimensions, tolerances, weight, finishes and the acoustic figures as stated.
Series 40 Elevation - 12 mm Glass
Front and end elevation. Line drawing plus a rendered view of the same drawing, two pages.
Frameless Glass Wall - 10 mm Elevation and Section
Elevation and vertical section for the 10 mm glass variant, two pages.
Frequently asked questions
What is a movable frameless glass wall?
Is there a floor track?
What glass thickness do I need?
How tall and how wide can a panel be?
How much sound does a frameless glass wall block?
Is this the same as a framed operable glass wall?
Can I have a door without opening the whole wall?
What tolerances should the design allow for?
What do you need to quote my opening?
Can my own team install it?
Where does this product sit in a construction specification?
What should a submittal include?
How do the panels park when the wall is open?
Need a frameless glass wall for your opening?
Send the opening dimensions, the ceiling build-up at the track line and your subdivision plan. We will confirm the panel schedule, hanger points, glass build and the detail at the head and floor.