Operable Glass Walls  /  Frameless system

Movable Frameless Glass Wall

A top-hung wall of individual 10 mm or 12 mm toughened glass panels that slide and park with no floor track. The glass is held only at its top and bottom edges, with no vertical frame between panels.

Buyers ask: “I want to divide a room with glass, but I do not want a track in the floor or frames blocking the view.”
Floor track
None — top-hung
Glass
10 / 12 mm toughened
Max height
3 000 mm
Panel width
700 – 1 200 mm
Installed movable frameless glass wall in a bright interior: individual toughened glass panels with no vertical frames, an overhead aluminium track, floor pins and partial band manifestation
Installed frameless glass wall with no vertical frames: overhead aluminium track, floor pins and partial band manifestation. Project photograph, shown as a product illustration rather than a named client project.

What is a movable frameless glass wall?

A movable frameless glass wall is a top-hung, individually operated glazed partition. Each panel is a single pane of 10 mm or 12 mm toughened safety glass, clipped into a 25 mm × 25 mm aluminium head and floor channel with a clear PVC gasket. Roller carriers in an overhead track carry the weight; a floor pin locates each panel when the wall is closed. There is no running track in the floor. Panels are 700–1 200 mm wide, up to 3 000 mm high, and the assembly is 25 mm overall.

Open the wall and the panels slide along the track and park out of the way, leaving one large space. Close it and the panes meet at a clear dry PVC joint, so the wall reads as one continuous sheet of glass.

In plain English

Imagine a wall made almost entirely of glass. Every pane hangs from the ceiling, so the floor underneath stays completely clear — nothing to trip over and no channel to collect dirt. When you want one big room, the panes slide away and park. Put them back and the room divides again. There are no metal posts between the panes, only a narrow clear joint.

“Movable”

Each panel is individually operated, slides along the overhead track and parks away. It is not a fixed partition.

“Frameless”

No vertical aluminium frame around or between the panes. The glass is clipped at its top and bottom edges only.

“Glass wall”

The glazing is the wall, not a window set into a wall. Daylight and the view pass through.

Other names for the same product

Architects, contractors and search engines use several names for this one system. If your documents use any of the wording below, you are in the right place:

frameless movable glass partitionframeless sliding glass wallsliding glass partition wallmovable glass partitionall-glass operable partitiontop-hung glass partition walltrackless glass wallframeless glass room divider
What it is not. It is not a framed operable glass wall with double-glazed units and a visible aluminium frame, not a fixed or demountable glass office partition that stays in place, and not a folding exterior glass wall. Those are different systems with different published data.

Why specify a frameless glass wall?

Three reasons buyers choose this system over a framed glass wall or a fixed partition.

01

No floor track

The floor stays completely clear. There is no recessed channel to clean, no trip hazard and no break in the floor finish — the view and the flooring run straight through.

Top-hung; panels located by floor pin.
02

One continuous glass face

With no vertical frames between panels, the wall reads as a single sheet of glass. It suits spaces where the architecture should stay visible.

Single toughened glass; clear dry PVC panel joint.
03

Daylight and flexibility

Keep borrowed light and a long sightline, then divide the room only when you need to. Panels park out of the way when the space is open.

700–1 200 mm modules; up to 3 000 mm high.

How it works, from ceiling to floor

Four details explain the whole system, then an enlarged view of the hanger-to-clamp connection. The photographs show the actual components.

Product photograph - twin roller hanger, threaded rod and glass clamp
Product photograph - twin roller hanger, threaded rod and glass clamp
Step 01

The ceiling carries the weight

A track is fixed to the structure above the ceiling line. Roller carriers run inside it and each glass panel hangs from its carrier on an adjustable threaded rod.

Top-hung / top-supported system. The load path above the track must be verified by the project structural engineer.

Product photograph - clamp blocks
Product photograph - clamp blocks
Step 02

The glass is held at two edges only

Short aluminium clamp blocks grip the top and bottom edges of the glass, with a clear PVC gasket between metal and glass. Nothing runs up the sides of the pane.

Pre-finished 25 mm × 25 mm aluminium head and floor channel; clear PVC glazing gasket.

Product photograph - floor lock set
Product photograph - floor lock set
Step 03

One pin in the floor, not a track

When the wall is closed, a floor pin locates the panel at a single point. A keyed floor lock secures the closing panel. The rest of the floor stays clear.

Panel can be fixed to the ground by floor pin. No track on the floor.

Product photograph - pass door hinge
Product photograph - pass door hinge
Step 04

Panes meet at a clear joint

Adjacent panes meet at a clear dry PVC joint, so the wall reads as one continuous sheet of glass. A hinged glass pass door gives access without moving the panels.

Clear dry PVC joint; satin stainless steel lever latch and hinge.

Trolley-to-clamp connection — step 1, enlarged

Two roller assemblies sit on each glass clamp, spaced along the panel width. A threaded rod passes through both rollers and is locked into the clamp top with a nut and washer; the rollers run inside the suspended overhead track. In plain English: the ceiling track carries the wheels, the rod hangs the clamp, and the clamp holds the glass.

Annotated trolley-to-clamp connection drawing for a movable frameless glass wall
Annotated component view of the trolley-to-clamp connection. The printed thread designation, clearance and slot references are descriptive labels on this component view — they are not NEUWALL product data and are not project dimensions. The only numeric product values for this system are in Technical specifications; the project detail is confirmed on the shop drawing.

Frameless or framed — which one do I need?

Both are operable glass walls. The right choice depends on what leads the design: the look, or the published acoustic rating.

ItemFrameless (this page)Framed operable glass wall
GlazingSingle 10 mm or 12 mm toughened glassDouble-glazed unit in an aluminium frame
Vertical frame between panelsNone; clear dry PVC jointVisible aluminium frame
Floor trackNoneNone
Published acoustic ratingStated on this pageHigher published Rw rating; stated on its own product page
Choose it whenDaylight and a minimal all-glass look leadA higher stated acoustic rating leads
One deliberate omission: this page does not repeat the frameless-versus-framed numbers as a cross-system comparison. Each product page states its own published figures against the standard that was tested. Use the parent Operable Glass Walls page to choose a type, then read the figures on the product page you select.

Technical specifications

Every value below is taken from the two-page NEUWALL frameless glass partitioning source sheet supplied for this product. The right-hand column names the section it comes from.

ItemValue as statedWhere it is stated
System typeTop-hung; no floor trackGeneral Description, source sheet
Glass10 mm or 12 mm single toughened safety glass, depending on height requiredGlazed Module
FrameworkPre-finished 25 mm × 25 mm aluminium head and floor channelFramework
Glazing gasketClear PVC glazing gasket to head and floor channelGlazed Module
Panel jointClear dry PVC jointPanel Joint
Panel width (module)700 mm – 1 200 mm maximumModule
HeightUp to 3 000 mmHeight
Overall thickness25 mmThickness
Dimensional tolerance± 5 mmTolerance
WeightApproximately 25.00 kg/m² for 10 mm glass; 30.00 kg/m² for 12 mm glassWeight
Floor fixingPanel can be fixed to the ground by floor pinGeneral Description
Glass flatnessToughened glass cannot be supplied completely flat. Maximum permitted deviation from a straight line is 0.30% (3 mm per metre run), measured across the full pane on the concave surface and in the vertical plane, supported at all four edgesGlass Tolerances
Vertical edge tolerance3 mm – 5 mm to frameless glass doors, assuming a flat and level floor and ceiling; may increase subject to prevailing site conditionsGlass Tolerances
Acoustic – 10 mmUp to Rw 32 dBAcoustic Performance
Acoustic – 12 mmUp to Rw 33 dBAcoustic Performance
Pass doorHinged glass pass door; satin stainless steel lever latch and hinge as standard; additional finishes and levers available as optional extraAccessories
FinishesSatin anodised or polyester powder coating to all exposed aluminium components, in a wide range of colours as standardFinishes
ManifestationA wide range of film manifestation and screen printing available as an optional extraAccessories
Reading the table. These are product data for the tested and described assembly, not a project guarantee. Figures in millimetres are as printed in the source sheet. Dimension callouts on the drawings further down this page are quoted separately as printed and are not merged into this table.

What the acoustic figures mean

A single pane of glass does not isolate sound the way a solid or double-glazed operable wall does. Here is exactly what the source sheet states.

up to Rw 32 dB
A glass module with 10 mm glass, as stated in the source sheet.
up to Rw 33 dB
A glass module with 12 mm glass, as stated in the source sheet.
Two rules we do not bend. “Up to” is the wording in the source sheet; it is a limit, not a promise for every installation. Rw is the laboratory sound reduction index to ISO 717-1. It is not an STC value under ASTM E413 / E90, and we do not convert, average or derive one rating from the other, or quote one fire or acoustic classification as equivalent to another. If your project specifies STC, send the requirement and we will tell you what can actually be documented for the build.

Installed performance also depends on the surrounding structure, the head detail and how the perimeter is sealed — none of which is a property of the glass panel alone. For the difference between the two rating systems, see the STC Acoustic Guide.

Plain-language glossary

The terms that appear in specifications and in our quotations, without the jargon.

Top-hung
All the weight hangs from a track fixed above the ceiling. The floor carries no running track.
Floor pin
A single small pin that locates a closed panel at one point in the floor. It is not a rail.
Module
The width of one glass panel. Here 700 mm to 1 200 mm maximum.
Manifestation
A visible film or printed pattern on the glass, so people notice the pane and a clear wall can still give some visual privacy.
Rw
A laboratory sound reduction index measured to ISO 717-1. It is a different rating from STC (ASTM E413 / E90) and the two are not interchangeable.
Pass door
A hinged glass door built into the wall, so you can walk through without moving any panels.

Technical drawings

The same NEUWALL Series 40 elevation shown twice: a line drawing for the drawing register, and a rendered view for a quick visual check.

NEUWALL Series 40 frameless movable glass wall front and end elevation line drawing for 12 mm thick glass
Line drawing. Printed title: "NEUWALL SERIES 40 FRAMELESS MOVABLE GLASS WALL (12mm THICK GLASS)". Front elevation and end elevation.
Rendered front and end elevation of the NEUWALL Series 40 frameless movable glass wall with 12 mm toughened glass
Rendered view of the same drawing. Shows the overhead track, the clamped glass edges and the floor pin as a visual reading aid; it is an illustration, not a photograph of an installation.

10 mm glass build

The supplied material also includes an elevation and a vertical section for the 10 mm variant. They are shown separately because the callouts belong to that build and are not carried into the specification table above.

Frameless glass wall 10 mm elevation line drawing showing two adjoining glass panels and the floor pin
10 mm elevation, line drawing. Shows two adjoining panels, the 10 mm glass callout and the floor pin. Figures as printed on the sheet.
Frameless glass wall 10 mm vertical section drawing showing the overhead track, clamp, glass and floor pin
10 mm vertical section, line drawing. Overhead track, glass clamp, pane and floor pin in section. Callouts including min. 150, 100, 40, 20 and 16 are reproduced as printed; units are not stated for every callout on the sheet.
Figures on the drawings. Callouts such as 12 mm toughened glass, 5 NOM and 17.5 NOM are reproduced exactly as printed on the sheet. The sheet does not state the units for every callout — confirm units against the shop drawing before ordering. The 10 mm elevation and section set shown above is also supplied as a two-page PDF in Downloads.

Components and hardware

Four more close-up views of the overhead track and its running gear. The twin roller hanger, clamp blocks, floor lock and pass door hinge are shown in How it works above.

Roller carriers in track
Roller carriers in trackRoller carriers running inside the overhead aluminium track, with the threaded suspension rod. · Product photograph
Track section
Track sectionCut-through view of the overhead track showing the wheel set running inside the extrusion. · Product photograph
Trolley and floor socket
Trolley and floor socketA four-wheel trolley shown beside the brass floor socket that receives the locating pin. · Product photograph
Aluminium channel profile
Aluminium channel profileExtruded head and floor channel profile, shown in cross-section. · Product photograph

Where it works

Specified wherever a space has to divide without losing daylight or the sightline.

Interior view through a movable frameless glass wall towards a pool and landscaped courtyard
Frameless glass wall dividing an interior from a pool terrace. Project photograph; shown as an application example, not as a named client project.
Hotel and event spaces

Keep daylight in a lobby or pre-function area, then close the glass wall for a private function without adding a visible frame.

Offices and meeting rooms

Divide a boardroom or collaboration space while keeping visual connection and borrowed light.

Showrooms and retail

Create a clean glazed frontage that can be opened up for events or product launches.

Residential and leisure

Separate an interior from a courtyard, pool or terrace without breaking the view or the floor finish.

Finishes, glass and door options

Fixed at order stage so the shop drawing matches what is manufactured.

Glass build

10 mm or 12 mm single toughened safety glass, selected according to the height required. Both builds are covered by the source sheet.

Aluminium finish

Satin anodised or polyester powder coating to all exposed aluminium components, in a wide range of colours as standard.

Manifestation

A wide range of film manifestation and screen printing is available as an optional extra. Useful for safety marking and partial visual privacy.

Door furniture

Satin stainless steel lever latch and hinge as standard in the sheet; additional finishes and levers are an optional extra.

Installation, tolerances and what we need from you

Glass is heavy, and it is never perfectly flat. These points belong in the design, not in a snag list.

  • Structure above the track. The system is top-hung. The load path above the track must be verified by the project structural engineer before the ceiling is closed.
  • Flat and level floor and ceiling. The 3–5 mm vertical edge tolerance to frameless glass doors assumes a flat and level floor and ceiling. Site conditions may increase it.
  • Glass flatness. Toughened glass cannot be supplied completely flat. The maximum permitted deviation from a straight line is 0.30% (3 mm per metre run), measured across the full pane on the concave surface and in the vertical plane, supported at all four edges.
  • Overall tolerance. ± 5 mm. Allow for it at the head, the jambs and the floor pin positions.
  • Handling. Panels weigh approximately 25.00 kg/m² for 10 mm glass and 30.00 kg/m² for 12 mm glass. We recommend a trained installer with glass handling equipment, and we do not recommend site self-assembly by a team without operable glass wall experience.

To issue a quotation and a shop drawing

Send the opening width and finished height, the ceiling or soffit build-up at the track line, the subdivision plan with the parking position, your preferred glass build, the pass door position and swing, and the finish. We will return the panel schedule, hanger points and the head and floor details.

How is this product specified?

A compact checklist for architects, specifiers and contractors working from a North American three-part (General / Products / Execution) project manual.

01 · Where it sits in the project manual

In a North American project manual this product type is specified under Division 10 (Specialties), Operable Partitions; CSI-format technical data for glazed operable partitions prints the section as 10 22 26. Confirm the number against the MasterFormat edition used on your project.

Related work is normally split across Division 03 (concrete tolerances), Division 05 (primary structural support and pre-punched steel at the track line), Division 06 (head and jamb blocking), Division 08 (lock cylinders and keying) and Division 09 (ceiling and wall framing).

02 · What a submittal should include

Product data for every panel, component and accessory: materials, construction, finishes, installation and operating instructions.

Shop drawings with plans, elevations, sections, attachment details, opening and storage dimensions, panel weights, required clearances, hardware and track positions, floor tolerances and direction of travel. Setting drawings for embedded items and the support beam template, finish samples, and an operation and maintenance manual at handover.

03 · Standards commonly referenced

Specification writers commonly cite ASTM E557 for opening preparation and installation of operable partitions, ANSI Z97.1 and CPSC 16 CFR 1201 for safety glazing, ASTM C1036 and ASTM C1048 for the glass, and ASTM B221 for aluminium extrusions.

These are standards named in a project specification context; they are not test results for this product. Confirm which edition applies to your project.

04 · What we return

A project-specific submittal set: product data, shop drawings (plans, elevations, sections, attachment details, panel weights, hardware and track positions), setting drawings, finish samples and an operation and maintenance manual.

Send the opening dimensions, ceiling build-up, subdivision plan, glass build, pass door position and finish. We return the full set before manufacture.

Downloads

The source sheet and both drawing sets supplied for this product. Ask us for a project-specific shop drawing set for your opening.

Movable Frameless Glass Wall - Technical Data

The two-page source sheet: construction, glass, dimensions, tolerances, weight, finishes and the acoustic figures as stated.

/AppUpload/File/ddbe2464400849cca24939d00d4e5b85.pdf

Series 40 Elevation - 12 mm Glass

Front and end elevation. Line drawing plus a rendered view of the same drawing, two pages.

/AppUpload/File/1e513b84f68b49a9a278c4dc8467d380.pdf

Frameless Glass Wall - 10 mm Elevation and Section

Elevation and vertical section for the 10 mm glass variant, two pages.

/AppUpload/File/beecd5dfced54a719be1526f98a26616.pdf

Frequently asked questions

What is a movable frameless glass wall?
A top-hung partition made of individual 10 mm or 12 mm toughened safety glass panels. Each panel is clipped at its top and bottom edges into a 25 mm × 25 mm aluminium channel, carried by rollers in an overhead track, and located at the floor by a pin. There is no running track in the floor and no vertical frame between the panels. The panels slide along the track and park out of the way when you want one large room.
Is there a floor track?
No running track is recessed into the floor. The panels hang from an overhead track and a floor pin locates each panel when the wall is closed. The source sheet also lists a 25 mm × 25 mm aluminium floor channel that clips the bottom edge of the glass; that is a panel-edge clamp, not a guide rail set into the floor. We confirm the exact detail on the shop drawing for your opening.
What glass thickness do I need?
Either 10 mm or 12 mm single toughened safety glass, selected according to the height required. The 12 mm build is heavier at approximately 30.00 kg/m² against 25.00 kg/m² for 10 mm. Send the finished height and we will confirm which build we would quote.
How tall and how wide can a panel be?
The sheet gives a maximum height of 3 000 mm and a module (panel width) of 700 mm to 1 200 mm maximum, with a dimensional tolerance of ± 5 mm. Anything above those limits needs a different system, so send the opening dimensions before the design is fixed.
How much sound does a frameless glass wall block?
The source sheet states that a glass module with 10 mm glass can achieve up to Rw 32 dB, and a module with 12 mm glass will achieve up to Rw 33 dB. "Up to" is the wording in the sheet. Rw is the laboratory sound reduction index to ISO 717-1; it is not an STC value under ASTM E413 / E90 and we do not convert, average or derive one from the other. Installed performance also depends on the surrounding structure, the head detail and perimeter sealing. See the STC Acoustic Guide.
Is this the same as a framed operable glass wall?
No. This system uses a single pane of glass with no vertical frame between panels. A framed operable glass wall uses double-glazed units in an aluminium frame and carries a higher published acoustic rating, at the cost of visible framing. We do not put a numeric cross-system comparison on this page; each product page states its own published figures. See Manual Operable Glass Partitions.
Can I have a door without opening the whole wall?
Yes. A hinged glass pass door can be included so people move through the wall without relocating the panels. The source sheet lists a satin stainless steel lever latch and hinge, with additional finishes and levers available as an optional extra. Door position and swing are fixed at order stage.
What tolerances should the design allow for?
Three separate ones. Toughened glass cannot be supplied completely flat: the maximum permitted deviation from a straight line is 0.30% (3 mm per metre run), measured across the full pane on the concave surface and in the vertical plane, supported at all four edges. Allow 3 mm to 5 mm vertical edge tolerance to frameless glass doors assuming a flat and level floor and ceiling; that may increase with site conditions. Overall dimensional tolerance is ± 5 mm.
What do you need to quote my opening?
The opening width and finished height, the ceiling or soffit build-up at the track line, the subdivision plan showing where the wall closes and where the panels park, your preferred glass build, the pass door position and swing, and the finish. With those we return the panel schedule, hanger points and the detail at the head and floor.
Can my own team install it?
Toughened glass panels weigh approximately 25 to 30 kg/m² and have to be hung, levelled and pinned on site. We recommend installation by a trained installer with the correct glass handling equipment, and we do not recommend site self-assembly by a team without experience of operable glass walls. Ask us for the installation scope when you request a quote.
Where does this product sit in a construction specification?
In a North American project manual it is normally specified under Division 10 (Specialties), Operable Partitions; CSI-format technical data for glazed operable partitions prints the section as 10 22 26. Confirm the number against the MasterFormat edition used on your project. Interfaces with structural support at the track line, head and jamb blocking, ceiling framing and lock cylinders belong in the related divisions. See How is this product specified?.
What should a submittal include?
Product data for every panel, component and accessory; shop drawings showing plans, elevations, sections, attachment details, opening and storage dimensions, panel weights, clearances, hardware and track positions, floor tolerances and direction of travel; setting drawings for embedded items and the support beam template; finish samples; and an operation and maintenance manual at handover. Send us your specification and we will return the project-specific set.
How do the panels park when the wall is open?
The parking arrangement is fixed at design stage, not on site. Common arrangements are a 90-degree or 135-degree side stack, a parallel side stack, or a recessed storage pocket; the run closes on either a hinged pivot panel or a lead panel at the pocket. Pocket depth, track switches and curves, and the clear floor area are shown on the shop drawing. Include the parking position on the subdivision plan you send us for a quote.

Need a frameless glass wall for your opening?

Send the opening dimensions, the ceiling build-up at the track line and your subdivision plan. We will confirm the panel schedule, hanger points, glass build and the detail at the head and floor.