Operable Partition Walls: Usage Guidelines and TroubleshootingA top-hung operable partition is a mechanical assembly that is deployed, sealed and parked many times over its service life. Most day-to-day issues are traced to three things: dirt in the overhead track, seals left engaged while a panel is moved, or an adjustment made to hanger hardware without the manufacturer's instruction.Essential usage guidelines1. CleaningClean panel faces with a soft, lint-free cloth and a mild, non-abrasive cleaner approved for the specified finish.Do not use abrasive cleaners, solvents, harsh chemicals or excessive water.Keep the overhead track free of dust and debris. Never wash down a track.2. OperationMove panels slowly, one at a time, and do not stop a panel in a track intersection.Never move a panel while its seals are engaged.NW831 and NW840 are manual systems; semi-automatic and fully automatic operation applies to NW840-W only.3. EnvironmentMaintain the temperature and humidity conditions stated in the O&M documentation.Keep the storage/parking area clear.Common issues and what to check firstPanels stick or are hard to moveConfirm all levers are in the vertical (retracted) position.Check the overhead track for dust, debris or foreign objects.If resistance persists, stop and call for service.Unusual noise during operationCheck for foreign objects in the track and for panels out of alignment.Use only the lubricant specified in the O&M documentation.Panels do not line up when closedCheck that vertical joints are free of debris.Do not adjust hanger hardware yourself — record the panel numbers and request a service visit.When to contact NEUWALLSignificant misalignment that remains after the checks above.Noise or resistance that persists after the track has been cleaned.Panels that will not stay in position, or seals that will not fully retract.Contact NEUWALL: Email: jerry@neuwall.com · Phone / WhatsApp: +86 15901822516.